• Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
  • Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
  • Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
  • Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
  • Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
  • Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump

Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump

After-sales Service: 2 Years
Warranty: 2 Years
Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Motor
Material: Stainless Steel
Samples:
US$ 25000/Piece 1 Piece(Min.Order)
| Request Sample
Diamond Member Since 2023

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 1 patents, you can check the Audit Report for more information
to see all verified strength labels (17)
  • Overview
  • Product Description
  • TECHNICAL DATA
  • OUR CERTIFICATE
  • FACTORY SHOW
  • FAQ
Overview

Basic Info.

Model NO.
FSD
Structure
Multistage Pump
Assembly
Booster Pump
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Submersible Pump, Clarified Water Pump, Sewage Pump, Chemical Pump
Industry
Air Conditioning Pump
Media
Sewage Pumps
Performance
Wear Pump
Theory
Centrifugal Pump
Impeller
Stainless Steel
OEM
OEM Is Welcome
Transport Package
Wooden Box
Specification
SS304
Trademark
FANCY
Origin
China
HS Code
8413709990
Production Capacity
1000000

Product Description

Product Description

MAIN CHARACTER:
1. Diesel engines have proven to be very reliable and effective for driving fire pumps
2. Diesel engines are currently the only type of internal combustion engine permitted by NFPA 20
3. Each engine shall be provided with two storage battery units according to NFPA20
4. Diesel engines for fire pump is of the compression ignition type
5. Advanced direct injection and combustion system.

Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump

 

TECHNICAL DATA
    
   
MODEL
MODELO
MODELE
DN Implr
Φ
Power
Potencia
Puissance
     Q=DELIVERY/CAUDAL/DEBIT
GPM 0 25 50 75 100 120 150  200 250 300  350 400 450 500  600
I/min 0 95 190 283 383 450 567  750 950 1133 1317 1517 1700 1900 2267
m³/h  0 5.7 11.4   17  23   27   34   45   57 68   79  91 102 114 136
mm mm kw hp       H=Head/Altura/Hauteur(m) -
FSD 32-250/55 50x32 208 6.3 8.6 60 60 58 52 39 - - - - - - - - - -
FSD 32-250/75 50x32 230 7.2 10 69.5 69.5 68 64 56 - - - - - - - - - -
FSD 32-250/92 50x32 237 8.2 12 75 75 73.5 70 61 - - - - - - - - - -
FSD 32-250/110 50x32 250 8.2 12 90 89 86 80 69 - - - - - - - - - -
FSD 32-250/150 50x32 258 20 27 97 96.8 94 88 76 - - - - - - - - - -
FSD 40-250/110 65x40 230 8.2 12 72 - - 68 66 63.5 59 50 - - - - - - -
FSD 40-250/150 65x40 250 20 27 84.5 - - 79.5 77.5 75.2 71.5 63 - - - - - - -
FSD 40-250/185 65x40 258 20 27 90 - - 86 83.5 80.7 77 68 - - - - - - -
FSD 40-315/185 65x40 260 20 27 95 - - 95 94 92.5 88 74 - - - - - - -
FSD 40-315/220 65x40 275 24 32 106 - - 105 104 103.5 99 86 - - - - - - -
FSD 40-315/300 65x40 290 28 38 120 - - 120 119 117 116 108 - - - - - - -
FSD 40-315/370 65x40 322 42 58 144 - - 144 143 142 139 134 - - - - - - -
FSD 40-315/450 65x40 340 45 61 160 - - 160 160 159 158 154 - - - - - - -
FSD 50-250/150 65x50 228 20 27 68.5 - - - - - 65 62 58 53 45 - - - -
FSD 50-250/185 65x50 235 20 27 79 - - - - - 77 74 71 66 59 47 - - -
FSD 50-250/220 65x50 250 24 32 89.5 - - - - - 88 85 81.5 76 68 57 - - -
FSD 50-250/300 65x50 258 28 38 95.5 - - - - - 92 90 87 81 74 63 - - -
FSD 50-315/370 65x50 284 42 58 114 - - - - - 111 108 104 98 92 84 - - -
FSD 50-315/450 65x50 306 45 61 132 - - - - - 129 125.5 122 117 110 102 - - -
FSD 50-315/550 65x50 322 55 75 146 - - - - - 143 140 136 132 125 116 - - -
FSD 50-315/750 65x50 340 75 100 164 - - - - - 162 158 154 148 141 134 - - -
FSD 65-250/220 80x65 225 24 32 64.8 - - - - - - - 63.5 62 61 58.5 56 52.5 -
FSD 65-250/300 80x65 244 28 38 80 - - - - - - - 79 78 77 74.5 72 70 59
FSD 65-250/370 80x65 258 42 58 92 - - - - - - - 89.5 88.5 87 85 83 80 69
 
MODEL
MODELO
MODELE
DN Implr
Φ
Power
Potencia
Puissance
Q=DELIVERY/CAUDAL/DEBIT
GPM 0 250 400 500 600 700 850 950 1000 1250 1350 1500 1750 2000 2500 3000 3500 4500
I/min 0 950 1517 1900 2267 2833 3217 3600 3783 4733 5100 5683 6617 7567 9467 11350 13250 17033
m³/h  0 57 91 114 136 170 193 216 227 284 306 341 397 454 568 681 795 1022
mm mm kw hp H=Head/Altura/Hauteur(m)
FSD 65-315/450 80x65 262 45 61 102 98 94.5 90 83 - - - - - - - - - - - - -
FSD 65-315/550 80x65 290 55 75 122 120 114.5 111 104 85 - - - - - - - - - - - -
FSD 65-315/750 80x65 317 75 100 141 141 134.5 132 123 105 86 64 - - - - - - - - - -
FSD 65-315/900 80x65 328 90 125 151 150 144.5 141 133 115 95 74 - - - - - - - - - -
FSD 80-250/450 100x80 240 45 61 88 86.7 86 84 80 72 62 49 - - - - - - - - - -
FSD 80-250/550 100x80 258 55 75 94.5 94.5 94.5 92 89 82 76 66 - - - - - - - - - -
FSD 80-250/750 100x80 276 75 100 108.5 108.5 108.5 106 103 96.5 90 80 - - - - - - - - - -
FSD 80-315/550 100x80 270 55 75 98 97 95.6 95 92 86 78 67 - - - - - - - - - -
FSD 80-315/750 100x80 295 75 100 124 123 121.6 119 116 110 103 94.5 89 - - - - - - - - -
FSD 80-315/900 100x80 320 90 125 144 143 141.6 140 137 130 122 114 108 - - - - - - - - -
FSD 80-315/1100 100x80 328 110 150 153 152 150.6 149 146 140 132 123 118 - - - - - - - - -
FSD 100-250/550 125x100 240 55 75 77 76 75.5 76 75 73 72 70 70 62.3 59 - - - - - - -
FSD 100-250/750 125x100 257 75 100 91 91 90.5 89.7 88 86 84 82 81 71.7 68.5 56 - - - - - -
FSD 100-250/900 125x100 270 90 125 100 100 99.5 98 97 95 93 91 90 80.7 77.5 65 - - - - - -
FSD 100-315/1100 125x100 300 110 150 118 - - 116 115.5 114 112 111 110 104 102 95 - - - - - -
FSD 100-315/1320 125x100 315 125 170 129 - - 127 126 124 123 122 121 115 112 105 - - - - - -
FSD 100-315/1600 125x100 328 165 225 148 - - 146 145 144 142 141 140 134 132 125 - - - - - -
FSD 125-250/750 150x125 255 75 100 80 - - 77 76 74.5 73 72 71 67 65 60 - - - - - -
FSD 125-250/900 150x125 265 90 125 87 - - 84 83 81.5 80 78.5 78 73.5 71.5 67.5 60 - - - - -
FSD 125-250/1100 150x125 274 110 150 97 - - 94 93 92 90.5 89 88 84 83.5 78.5 71 - - - - -
FSD  125-250H/1100 150x125 240 110 150 74 - - 74.5 74 74 73 73 72.5 70.8 70.4 69 66 62.5 53 - - -
FSD  125-250H/1320 150x125 260 125 170 84 - - 84 84 83.5 83 82.5 82 80.8 80.4 78.5 76 72 63 - - -
FSD  125-250H/1600 150x125 280 165 225 98 - - 97.5 97.5 97.5 97 97 96.5 94.8 94.4 93 90 87 78 66 - -
FSD  125-315/1320 150x125 280 125 170 96 - - - - - - 96 96 94 93.5 92 88.5 84 65 - - -
FSD 125-315/1600 150x125 295 165 225 112 - - - - - - 111.5 111 110 109.5 108 106 102 88 - - -
FSD 125-315/1850 150x125 310 200 270 125 - - - - - - 125 124.7 123 122.5 121.5 119 113 98 - - -
FSD 125-315/2000 150x125 328 200 270 136 - - - - - - 136 135.5 135 133.5 133 130 125 110 - - -
FSD 150-250/1320 200x150 265 125 170 80.2 - - - - - - - - - 78 75 73.5 71 67 61 54 37
FSD 150-250/1600 200x150 280 165 225 90 - - - - - - - - - 88 87 85 84 79 74 66 47
FSD 150-250/2000 200x150 295 200 270 100 - - - - - - - - - 97 96 95 93 89 84 76 56
FSD 150-315/1850 200x150 287 200 270 92 - - - - - - - - - 90 89 87.2 85 80 71 61 -
FSD 150-315/2500 200x150 305 250 340 111 - - - - - - - - - 110 108 106 104 98 90 82 62
FSD 150-315/2800 200x150 315 300 410 124 - - - - - - - - - 121 120 118 116 111 104 95 73
FSD 150-315/3150 200x150 327 300 410 135 - - - - - - - - - 134 133 132 130 124 116 107 84
 
 
 
OUR CERTIFICATE

 

Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump

FACTORY SHOW

OUR COMPANY

FANCY PUMP (ZHEJIANG) CO LTD located in Taizhou City, Zhejiang Province, specializes in producing and operating various water pumps and spare parts. The company's traditional & core business is the production of various types of pumps for different industries, such as households, buildings, gardens, HVAC, fire fighting and sewage, etc. Fancy Pump is widely used in agriculture irrigation, garden watering, HVAC, pipeline pressurization, building water supply, residential & commercial community, fire fighting, industrial wastewater treatment, sewage water treatment, etc. 
Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric PumpSingle-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
FANCY WATER PUMP PRODUCTS
COMMERCIAL PUMP INDUSTRIAL PUMP CIRCULATION PUMP SURFACE PUMP
domestic water pump price industrial pump hot water pump surface water pump
domestic water pump centrifugal pump swimming pool circulation pump surface pump
domestic monoblock pump electric motor pump circulation pump self-priming pump
household water pumps suction pumps water circulation pump vortex pump
domestic water pumps for sale centrifugal water pump circulation pump surface well pump
domestic water motor multistage pump water circulation pump surface mounted water pump
1 hp domestic water pump suction water pump pool circulation pump shallow water pump
domestic pump price centrifugal pump price recirculating pump self priming water pump
domestic water booster pump horizontal pump heating circulation pump surface bore pump
best domestic water pump centrifugal pump small water circulation pump self priming centrifugal pump
SUBMERSIBLE PUMP BOREHOLE PUMP POOL PUMP FIRE PUMP
submersible pump solar pumping system swimming pool water pump diesel water pump
submersible pump price solar water pump swimming pool pump diesel engine pump
submersible water pump borehole water pump swimming pool filter pump fire pump
submersible motor pump solar motor pump swimming pool motor pump fire fighting system
electric submersible pump solar pump swimming pump firefighter pumps
submersible pump solar borehole pumps prices outdoor pool pump fire pump price
submersible well water pump solar borehole pumps swimming pool pumps for sale fire pump
best submersible pump submersible borehole water pump best swimming pool pump jockey pump
sewage pump submersible borehole pumps swimming pool circulation pump fire fighting system
submersible drainage pump well pump solar swimming pool pump diesel pump set

PART OF OUR PRODUCTS 
Single-Stage Motor Diesel Engine Driven Split Case Sanitary Fire Fighting Electric Pump
FAQ

1. Q: What is the minimum order amount?
    A:$5000.
2. Q: Can you provide OEM service?
    A: Yes.
3. Q: What are your payment terms?
    A:30% T/T deposit by TT in advance, balance before delivery.
4. Q: What is the warranty of the product?
    A: 2 years after purchasing our pump.
5. Q: What is the delivery time?
    A: 30-45 after we receive your deposit.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Management System Certification
ISO9001:2015
Import & Export Mode
Have Own Export License